Impact Factor (2025): 6.9
DOI Prefix: 10.47001/IRJIET
This paper
involves the experimental and analytical study of flexural strength of Cold
Formed Steel (CFS) sections by using bolted connection. The analytical
investigation of the built up section was carried out using finite element
analysis software ABAQUS (Standard version 6.10) with 4 number of built up
sections. The specimens consists of beams made of one or more Cold-Formed Steel
(CFS) profiles namely, C (lipped channel) profiles and U (channel without lip)
profiles, whereas the channel sections are connected along the flanges with
bolts (M10). The experimental investigation shows the bending strength and
behavior of CF built-up sections where, Four models are created in two groups,
the first group of two specimens with 2mm thickness and second group of two
specimens with 3.15 mm thickness with varying web and flange dimensions taken
from IS 811-1987. They are analyzed under two point loading conditions. The
result shows the modes of buckling failure, their influence on the bending
strength and behaviour of CF built-up sections. The influence of the height,
thickness and span of the beams was studied and then experimental results are
compared with the analytical results.
Country : India